University Acoustic Pod RFQ: Specify Interview and Group Study Booths
Request separate prices for solo interview booths and shared study booths. Count simultaneous sessions after subtracting rooms that are actually free and suitable. Then give every bidder the same floor plan, delivery endpoint, installation responsibilities and acceptance checks. A four-seat booth can hold one study group; it cannot host four unrelated video interviews.
Before you share that plan with bidders, use the campus facilities review checklist to mark each proposed booth and match it to a use record and manufacturer’s drawing.
Count sessions in the same half hour
Ask the careers team for overlapping interviews and the library for overlapping group bookings. Record people physically in the room: a student speaking to three recruiters online still needs one local seat. For study groups, keep the party size as well as the number of bookings. A vacant two-seat room can take a pair, but it cannot take a group of four. Allocate each available room only once.
Session length matters. At Binghamton University’s Fleishman Career Center, a student can reserve a single-person pod for a phone or virtual interview for up to two hours. An in-person interview needs another setting. That is one university’s booking practice, not a recommended time limit. Use your own timetable to see whether a booth will still be occupied when the next interview starts.
Put the solo and group requirements on different quote lines
The University of Limerick’s procurement notice UL1063 called for solo and multi-person acoustic booths and included delivery, on-site installation and commissioning in its scope. It distinguished integrated lighting, power and ventilation from options such as seating, a work surface and a screen mount. The notice is a useful example of what to specify, not a statement that the same items come with every booth. Neither university is presented here as a MobileX customer.
| Quote line | MobileX starting point | What to put on the drawing or price separately |
|---|---|---|
| S: One student on a remote interview | MP1 for a compact call position; MP1+ for a roomier seated setup. Both include one desk and one seat. | Mark the occupied chair, laptop, camera position and background in view. Name the party supplying the laptop, camera and headset. Confirm usable desktop space against the actual equipment. |
| G: One group working together | MP2 for a pair; MP3 as a starting point for three or four people. Each is one shared room. | MobileX quotes meeting-pod seating and tables separately. Show the proposed seats and work surface in use. List a display, its mount and its data connection as separate items so a bracket is never priced as a complete screen. |
If either line must accommodate wheelchair access, tell bidders which activity and how many units it applies to. Request a furnished drawing showing the approach, finished clear door opening, threshold and turning space. Have the campus access team review it before model selection; a seat count or an exterior footprint cannot answer that question.
Copy this request for quotation
Send identical buyer entries to each bidder. Duplicate line S or G for a different building, group size or accessible configuration. Ask for one completed return per configuration and show shared site charges just once.
UNIVERSITY ACOUSTIC POD RFQ Campus / building / floor / room / destination country: Plan reference and revision: Required handover date: BUYER: COMPLETE ONE LINE PER CONFIGURATION Line ID and use (solo video interview / group study / other): Peak simultaneous sessions: ____ In-person users per session: ____ Suitable rooms allocated at that time: ____ New booths required: ____ Typical session length; task and equipment used: Furniture required; devices supplied by campus; options to price separately: Power, data, lighting, ventilation and access requirements: Mandatory evidence / acceptable alternatives: BUYER: GIVE ALL BIDDERS THE SAME SITE SCOPE Delivery endpoint (named dock, floor and final room): Access route, lift limits, permitted working hours and storage: Who unloads / moves inside / assembles / removes packaging: Who connects building power and data; who commissions the booth: Checks to pass in the finished room; witness and person signing acceptance: SUPPLIER: RETURN WITH YOUR QUOTATION Line ID / offered model and revision / quantity / unit and extended price: Included furniture and equipment; separately priced options: Exceptions or substitutions and effect on use, cost or timing: Evidence reference for each requirement (drawing, report or sample): Packing / freight / import charges and taxes / delivery endpoint: Unloading / inside movement / assembly / site connections / commissioning: For each service: named responsible party, included price or exclusion. Production, transit and site-work durations; assumptions and quote validity: Handover documents; warranty contact and scope; outstanding items and owner: Currency / tax basis / total for the agreed scope (or subtotal with gaps):
Worked example: a careers center and library share one order
Illustrative buyer entries, not an actual university order or a MobileX offer. Assume a Tuesday 10:00–10:30 peak: three students have separate interviews; one pair and one group of four need study space. The half hour is when demand overlaps, not the length of each booking. The existing interview room is free for the whole interview assigned to it, and the two-seat study room is free for the pair’s entire session. Both departments can use the proposed pod locations during that interval.
- S1 — two solo booths: 3 interviews − 1 available private room = 2. One person per booth for up to 90 minutes. Students bring laptops and headsets. Quote two MP1+ units or equivalent, each with a desk, seat, light, ventilation and local power outlet. Show the laptop position on the furnished drawing.
- G1 — one four-person booth: Assign the pair to the two-seat room. That leaves 1 four-person group − 0 suitable group rooms = 1 shared booth. Quote one MP3 or equivalent with a separately identified seating-and-table set for four. Show four open notebooks on the proposed table. Give a screen mount as an option; campus IT supplies the display.
- Delivery and work split: For this example, use a campus in Dublin, Ireland: north loading bay to first-floor Library Room 1.12 by service lift. Quote unloading, lift transfer, assembly, packaging removal and functional checks as separate lines. Campus facilities will supply the room power and campus IT the network. Ask each bidder to identify work it will undertake and work for a local installer. Campus will confirm lift capacity and a working slot before ordering.
- Evidence and acceptance: With the bid, request a furnished drawing for S1 and G1, the applicable acoustic evidence with its test method, and packed sizes and weights for the access check. At handover, facilities witnesses door operation, lighting and fans on each unit; careers and IT run a sample video call in S1; library staff check the four furnished places in G1. Record open defects by unit, assign an owner and agree a retest before signature.
Open the filled RFQ example (TXT)
The shortlist is two solo booths plus one group booth, not three interchangeable units. If the four-person table leaves too little working space on the drawing, revise G1 or use a suitable existing room. Keep S1 unchanged unless interview demand has also changed.
Compare bids at the room, not at the loading bay
Start with bids that meet both activity lines. Compare two S1 unit prices + one G1 unit price + required furniture and services not already included, on the same currency and tax basis. Keep optional items outside that total. A supplier offering dock delivery and video assembly guidance has quoted a different endpoint from one offering assembly in Room 1.12. Obtain a local price for the missing work or request a revised bid. Until then, label the first figure a subtotal; a blank cost is not zero.
Agree what counts as acceptance before award. A signed delivery note records receipt of crates. A room handover records that the specified configuration works in place. Where measurable speech privacy or another formal performance criterion is mandatory, name the test method, evidence and reviewer in the RFQ. A successful sample call is a functional check, not an acoustic certification.
For a MobileX comparison, shortlist the single-person work booth and the two- and four-person meeting pods. Paste your S and G lines into the project inquiry form, including the destination and the work your campus will handle. Ask for a model and furniture list per line, with local services shown separately.